kw.\*:("Lightning overvoltage")
Results 1 to 25 of 282
Selection :
Validation of Rusck's scalar and vector potential expressions due to a return stroke in a lightning channelHALDAR, M. K; LIEW, A. C.IEE proceedings. Part C. Generation, transmission and distribution. 1987, Vol 134, Num 5, pp 366-367, issn 0143-7046Article
Prüfungen mit Blitzstossspannung an fertig montierten 20-KV-Schaltanlagen der HEAG = Essai de surtension atmosphérique d'un poste de couplage à 20 kV complètement monté = Lightning surge testing of completely installed 20 kV switchgearKARMATSCHEK, B; BRAMMER, F. A.Elektrizitätswirtschaft. 1985, Vol 84, Num 8, pp 262-267, issn 0013-5496Article
Maximum lightning overvoltage along a cable due to shielding failureHENRIKSEN, Thor.Electric power systems research. 2007, Vol 77, Num 11, pp 1460-1465, issn 0378-7796, 6 p.Conference Paper
Lightning induced voltages on power lines: experimentMASTER, M. J; UMAN, M. A; BEASLEY, W et al.IEEE transactions on power apparatus and systems. 1984, Vol 103, Num 9, pp 2519-2529, issn 0018-9510Conference Paper
Evaluation of steep-front overvoltage waveforms for oil-filled transformersKAWASHIMA, T; OKABE, S; ZAIMA, E et al.IEE conference publication. 1999, pp 1.279.P4-1.282.P4, issn 0537-9989, isbn 0-85296-719-5Conference Paper
Reference Standard digital recorder with 200 MS/s - 12 bit for H.V. impulse testsSTRAUSS, W.IEE conference publication. 1999, pp 1.226.P4-1.229.P4, issn 0537-9989, isbn 0-85296-719-5Conference Paper
A simplified method for estimating lightning performance of transmission linesIEEE transactions on power apparatus and systems. 1985, Vol 104, Num 4, pp 919-932, issn 0018-9510Article
Propagation characteristics of impulse creepage discharge in N2/SF6 gas mixtureOKUBO, H; YOSHIDA, T; HAYAKAWA, N et al.IEE conference publication. 1999, pp 4.188.P2-4.191.P2, issn 0537-9989, isbn 0-85296-719-5Conference Paper
Study of the breakdown voltage of the air in high altitudes, applying lightning impulses (1.2/50μs) under conditions of controlled humidity and temperatureGARCIA, J; HERRERA, F; ORTIZ, H et al.IEE conference publication. 1999, pp 3.55.S7-3.58.S7, issn 0537-9989, isbn 0-85296-719-5Conference Paper
Extension of the Chowdhuri-Gross model for lightning induced voltage on overhead linesLIEW, A. C; MAR, S. C.IEEE transactions on power delivery. 1986, Vol 1, Num 2, pp 240-247, issn 0885-8977Conference Paper
Marx circuit modified by adding a tail sphere gap to generate lightning impulses lasting a few microsecindsCARRUS, A.IEE proceedings. Part A. Physical science, Measurements and instrumentation, Management and education, Reviews. 1985, Vol 132, Num 1, pp 40-44, issn 0143-702XArticle
Lightning induced voltages on power lines: theoryMASTER, M. J; UMAN, M. A.IEEE transactions on power apparatus and systems. 1984, Vol 103, Num 9, pp 2502-2518, issn 0018-9510Conference Paper
Frequency of occurrence of lightning overvoltages on distribution linesMATSUO, N. M; ZANETTA, L. C.IEE conference publication. 1997, pp 2.18.1-2.18.5, issn 0537-9989, isbn 0-85296-674-1Conference Paper
Alternative solution for the Chowdhurigross model of lighting-induced voltages on power linesHALDAR, M. K; LIEW, A. C.IEE proceedings. Part C. Generation, transmission and distribution. 1988, Vol 135, Num 4, pp 324-329, issn 0143-7046Article
Lightning surge calculations including corona effects using a two-conductor modelNAGAOKA, N; MOTOYAMA, H; AMETANI, A et al.Electric power systems research. 1987, Vol 13, Num 1, pp 31-41, issn 0378-7796Article
Circuit design of surge protector for 200 kb/s ping-pong transmission equipmentKAJIWARA, T; MAKI, K; SATOH, H et al.Review of the electrical communication laboratories. 1985, Vol 33, Num 2, pp 364-372, issn 0029-067XArticle
Calculation of lightning-induced voltages on overhead multiconductor systemsYOKOYAMA, S.IEEE transactions on power apparatus and systems. 1984, Vol 103, Num 1, pp 100-108, issn 0018-9510Article
The Use of Underbuilt Wires to Improve the Lightning Performance of Transmission LinesVISACRO, Silverio; SILVEIRA, Fernando H; DE CONTI, Alberto et al.IEEE transactions on power delivery. 2012, Vol 27, Num 1, pp 205-213, issn 0885-8977, 9 p.Article
UEBERSPANNUNGSSCHUTZ EINES NETZANSCHLUSSES FUER TRANSPORTABLE BETRIEBSSTAETTEN MIT SCHUTZISOLIERUNG BEI DIREKTEN BLITZEINSCHLAEGEN = LA PROTECTION CONTRE LES SURTENSIONS D'UN RACCORDEMENT AU RESEAU POUR ATELIER MOBILE AVEC ISOLATION POUR LES COUPS DE FOUDRE DIRECTSHASSE P; MEUSER A; PIVIT E et al.1982; ETZ, ELEKTROTECH. Z. (BERLIN, WEST); ISSN 0170-1711; DEU; DA. 1982; VOL. 103; NO 2; PP. 52-54; BIBL. 2 REF.Article
SURTENSIONS SUR LES LIGNES D'ABONNEDUTT J.1979; REV. TELECOMMUNIC.; FRA; DA. 1979; VOL. 54; NO 2; PP. 131-135; BIBL. 14 REF.Article
THE LIGHTNING PERFORMANCE OF ELECTRIC POWER TRANSMISSION LINES IN QUEENSLAND.DARVENIZA M; WATTS KW.1976; ELECTR. ENGNG TRANS.; AUSTRAL.; DA. 1976 PARU 1977; VOL. 12; NO 2; PP. 76-83; BIBL. 14 REF.Article
DER BLITZEINSCHLAG IM NAHBEREICH VON HOCHSPANNUNGSSCHALTANLAGEN = LES COUPS DE FOUDRE AU VOISINAGE D'UN POSTE DE COUPLAGE HAUTE TENSIONROEHSLER H; STRNAD A.1981; ELEKTRIZITAETSWIRTSCHAFT; ISSN 0013-5496; DEU; DA. 1981; VOL. 80; NO 10; PP. 311-316; ABS. ENG; BIBL. 11 REF.Article
LES ERREURS DE MESURE DES PARAMETRES DES DECHARGES ATMOSPHERIQUES NORMALISEESABADZHIDI GE; KUZHEKIN IP.1980; IZVEST. AKAD. NAUK S.S.S.R., ENERGET. TRANSP.; SUN; DA. 1980; NO 1; PP. 150-155; BIBL. 7 REF.Article
BLITZSCHUTZ VON FEBAEUDEN. = PROTECTION CONTRE LA FOUDRE DES CONSTRUCTIONSBAATZ H.1978; ELEKTROTECH. Z. A; DTSCH.; DA. 1978; VOL. 99; NO 2; PP. 77-79; ABS. ANGL.Article
ERZENGUNG SCHWINGENDER BLITZSTORSSPANNUNG UND DEREN ANWENDUNG IN DER HOCHSPANNUNGSTECHNIK = LA GENERATION D'UNE SURTENSION ATMOSPHERIQUE IMPULSIONNELLE ET SON UTILISATION EN TECHNIQUE HTGOCKENBACH E; MEPPELINK J.1983; ETZ-ARCHIV; ISSN 0170-1703; DEU; DA. 1983; VOL. 5; NO 4; PP. 135-140; ABS. ENG; BIBL. 14 REF.Article